ALLIANCE 170 Series Specifiche

Navigare online o scaricare Specifiche per Asciugatrici elettriche ALLIANCE 170 Series. ALLIANCE 170 Series Specifications Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 77
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
Installation/Operation/Maintenance
Tumble Dryers
120 Pound (54 Kilogram) Capacity
170 Pound (77 Kilogram) Capacity
200 Pound (91 Kilogram) Capacity
Starting Serial No. 0907003062
Refer to Page 8 for Model Identification
TMB1268C_SVG
Original Instructions
Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
www.alliancelaundry.com
Part No. 70458101ENR9
September 2014
Vedere la pagina 0
1 2 3 4 5 6 ... 76 77

Sommario

Pagina 1 - Tumble Dryers

Installation/Operation/MaintenanceTumble Dryers120 Pound (54 Kilogram) Capacity170 Pound (77 Kilogram) Capacity200 Pound (91 Kilogram) CapacityStartin

Pagina 2

T = Thermal OilIncludes models with the following control suffixesR3 – reversing DX4 OPL RE – reversing LED OPL RQ – reversing dual digital timerRD –

Pagina 3 - Front Matter

Safety Information Explanation of Safety MessagesPrecautionary statements (“DANGER,” “WARNING,” and“CAUTION”), followed by specific instructions, are

Pagina 4

• Always read and follow manufacturer’s instructions on pack-ages of laundry and cleaning aids. Heed all warnings or pre-cautions. To reduce the risk

Pagina 5 - Table of Contents

Specifications and Dimensions Specifications and DimensionsRefer to machine serial plate for additional specifications.Specifications 120 Series 170 S

Pagina 6

Specifications 120 Series 170 Series 200 SeriesSteam ModelsNet Weight (approximate): Pounds [kg] 1,375 [624] 1,675 [761] 1,808 [820]Steam Connection 3

Pagina 7

Cabinet Dimensions120L/N/E 31.38 in. [797mm]32.5 in. [826mm]48.91 in. [1,242mm]49.91 in. [1,268mm]67.92 in. [1,725mm]45.38 in. [1,153mm]120S 31.38 in.

Pagina 8 - Introduction

170 and 200 Series Tumble Dryer Dimensions and Exhaust Outlet LocationsTMB2397N_SVG1VYXWGFLHJKEDCIBA11. Top View of Exhaust DuctCabinet DimensionsM

Pagina 9

Electric and Gas Connection Locations for Gas Models Through 3/10/13TMB2255N_SVGDBCABDCA21TMB2382N_SVGADBC31. 120L/N2. 170L/N3. 200L/NModelsEle

Pagina 10 - Contact Information

ModelsElectrical Connection Gas ConnectionA B C D Diameter120L/N 18.34 in. [466mm]77.84 in. [1,977mm]12.5 in. [318 mm] 70.5 in. [1,791mm]1 in. NPT170L

Pagina 11 - Safety Information

ModelsSteam OutletDiameter B1 B2 D120S 3/4 in. NPT 34.625 in. [879 mm] 13.125 in. [333 mm] 68.5 in. [1,740 mm]170S 1 in. NPT 44.625 in. [1,133 mm] 8.7

Pagina 13 - Specifications and Dimensions

ModelsSteam OutletDiameter B1 B2 D120S 3/4 in. NPT 34.625 in. [879 mm] 13.125 in. [333 mm] 68.5 in. [1,740 mm]170S 1 in. NPT 44.125 in. [1,133 mm] 9 i

Pagina 14

Models A B120E 35.81 in. [910 mm] 85.64 in. [2,175 mm]Specifications and Dimensions Part No. 70458101ENR9© Copyright, Alliance Laundry Systems LLC -

Pagina 15 - Part No. 70458101ENR9

Installation Pre-Installation InspectionUpon delivery, visually inspect the crate, carton and parts for anyvisible shipping damage. If the crate, cart

Pagina 16

TMB2020N_SVG43156782NOTE: Shaded areas indicate adjacent structure.1. 0.5 in. [13 mm] recommended between machines for removal or installation2. A

Pagina 17

Call your local water company or the proper municipal authorityfor information regarding local codes.IMPORTANT: It is your responsibility to have ALLp

Pagina 18

To connect the two hoses (supplied with tumble dryer), insertrubber washers (from literature pack) in water inlet hose cou-plings. Refer to Figure 4 .

Pagina 19

TMB1999N_SVG1675431 21. Opening for Auxiliary Alarm Cable2. Fuse3. Auxiliary Alarm Fast-On Connection4. Test Button5. Light6. Reset Button

Pagina 20

ModelsPrepurge Time(seconds)Trial for Ignition(seconds)Reset LockoutCondition By:Models through3/10/13CE andAustralia18 10 025, 030, 035, 055:Press re

Pagina 21 - Models A B

configuration. Tumble Dryers are supplied from the factory foroperation on Natural Gas 1000 Btu/cu. ft. [8914 kcal/m 3], or L.P.Gas 2500 Btu/cu. ft. [

Pagina 22 - Installation

GasTypeGasFam-ilyGroupGasDesig-nationSupplyPressurein. wc[mbar,kPa]ManifoldPressurein. wc[mbar,kPa]Capaci-ty/ModelOrificeDiam-eterinch[mm]OrificePartN

Pagina 23 - TMB2020N_SVG

Front MatterInstallation must conform with local codes or, in the absence of local codes, with:In the U.S.A., installation must conform to the latest

Pagina 24

Properties of CE GasesGasTypeGasFami-ly GroupGasDe-scrip-tionGasDesig-nationWi Hi Ws Hs dWobbe In-dex(net)Heat-ingValue(net)Wobbe In-dex(gross)Heat-i

Pagina 25

TMB2328N_SVG43211. Gas Shut-Off Valve (Ahead of pressure tap) (Not Sup-plied)2. Pressure Tap3. Gas Shut-Off Valve (Shown in closed position) (No

Pagina 26

Burner OrificeTMB2015N_SVG11. Size Stamped on OrificeFigure 9Installation 32© Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT P

Pagina 27

Exhaust Requirements Exhaust RequirementsWARNINGA drying tumble dryer produces combustible lint. Toreduce the risk of fire, the tumble dryer must be e

Pagina 28

WARNINGImproperly sized or assembled ductwork causes ex-cess back pressure which results in slow drying, lintcollecting in the duct, lint blowing back

Pagina 29

T496I_SVGBAA211. Discard2. CoverFigure 11 Individual VentingFor maximum efficiency and performance, it is preferred to ex-haust tumble dryer(s) in

Pagina 30

Table 4 to determine equivalent ducting sizing. The collector ductmay be rectangular or square in cross section, as long as the areais not reduced. Pr

Pagina 31

Duct Station 120 Series 170/200 SeriesI 32 in. [813 mm] 36 in. [914 mm]J 33 in. [838 mm] 38 in. [965 mm]K 35 in. [889 mm] 40 in. [1,016 mm]L 36 in. [9

Pagina 32 - Figure 9

Gas Requirements Gas RequirementsWARNINGTo reduce the risk of fire or explosion, DO NOT CON-NECT THE GAS LINE TO THE TUMBLE DRYER IFTHE GAS SERVICE IS

Pagina 33 - Exhaust Requirements

Non-CEand Non-AustralianModelsAustralianand Kore-an ModelsCE Mod-elsRecommend-ed11 in. w.c. 2.74 kPa 27.4 mbarMinimum 10 in. w.c. 2.49 kPa 24.9 mbarFo

Pagina 34

WARNING• Installation of unit must be performed by a qualified installer.• Install tumble dryer according to manufacturer’s instructions and local cod

Pagina 35

Gas Supply Pipe Sizing and LoopingTMB2126N_SVG1 2 3 4 5 6 7 8 9M687453219 1011121. Gas furnace [120,000 Btu/hr. [127 Mj/hr., 35.2 kW]]2. Gas wate

Pagina 36

Gas Pipe Size Required for 1000 Btu Natural Gas — 0.64 Specific Gravity at 7 ± 1.5 inches [17.4 ± 4 mbar,1.74 ± 0.37 kPa] Water Column PressureGasAp-p

Pagina 37

Gas Pipe Size Required for 1000 Btu Natural Gas — 0.64 Specific Gravity at 7 ± 1.5 inches [17.4 ± 4 mbar,1.74 ± 0.37 kPa] Water Column PressureGasAp-p

Pagina 38 - Gas Requirements

Model GasAltitude OrificeNewRatefeet [m] No.inches[mm]Quantity Part No.Btu/hr.*[Mj/hr.]120L/N Natural Gas 2,001 – 4,000 [610 –1,220]18 0.1695 [4.3] 3

Pagina 39

Model GasAltitude OrificeNewRatefeet [m] No.inches[mm]Quantity Part No.Btu/hr.*[Mj/hr.]200L/N Natural Gas 2,001 – 4,000 [610 –1,220]12 0.1890 [4.8] 4

Pagina 40 - 1 2 3 4 5 6 7 8 9

Electrical Requirements Electrical RequirementsWARNINGTo reduce the risk of electric shock, fire, explosion,serious injury or death:• Disconnect elect

Pagina 41

WARNINGTo reduce the risk of electrical shock, de-energizethe electrical circuit being connected to the tumbledryer before making any electrical conne

Pagina 42 - High Altitude Orifice Sizing

Ground and Terminal Block Locations for CE Gas and Steam ModelsTMB2247N_SVG213451. Earth/Ground2. Junction Box3. Terminal Block4. Power Discon

Pagina 43

2. Connect the conduit-encased leads to the disconnect switch,or circuit breaker. Connect the wire leads to the appropriatelabeled terminal on the t

Pagina 44

Non-CE Models TMB2270N_SVG21 CE Models TMB2271N_SVG213 1. Ferrite Ring2. Junction Box3. Models Through 7/31/11Figure 20 Electrical Specification

Pagina 45 - Electrical Requirements

Table of ContentsIntroduction... 8Model Identification ...

Pagina 46

NOTE: 3 Phase Only – Each tumble dryer must be con-nected to its own individual branch circuit breaker, notfuses, to avoid the possibility of “single

Pagina 47 - Tumble Dryer

Serial Plate Rat-ingTerminal BlockConnections Re-quiredRated Current*(amps) Breaker RatingRecommendedWire Size AWG[mm²]400-415V/50Hz/3ph L1,L2,L3 and

Pagina 48 - Ferrite Ring Installation

Steam Requirements Steam RequirementsNOTE: Machines require a constant 80 to 100 psig [5.3to 6.9 bar] steam service for optimum operation. Themaximum

Pagina 49 - Electrical Specifications

120 Series Tumble DryersTMB2014N_SVG766351213121181094NOTE: Refer to Table 7 for sizing of steam lines. Piping must also be sized accordingly for leng

Pagina 50

Steam Pressure PSI [bar] Minimum Supply Pipe DiameterSteam Trap Size* Pounds Con-densate/Hour [Kilograms Con-densate/Hour]*Based on 6.9 bar.Table 7170

Pagina 51

Steam Pressure PSI [ bar]Minimum Supply Pipe DiameterSteam Trap Size*Pounds Condensate/Hour [Kilo-grams Condensate/Hour]80-100 [5.3-6.9] 1-1/4 in. NPT

Pagina 52 - Steam Requirements

Operating Instructions Operating InstructionsWARNINGTo reduce the risk of fire:• DO NOT DRY articles containing foam rubber orsimilarly textured rubbe

Pagina 53

b. Close loading door. Tumble dryer will not operate withthe door open.3. Determine Control Type and Temperature Settinga. Refer to the various cont

Pagina 54

IMPORTANT: To stop the tumble dryer at any timeduring the cycle, OPEN DOOR. If the loading door orlint panel door is opened during the cycle, the heat

Pagina 55 - Thermal Oil Prep

HIGHTemperature 180°F [82°C]MEDIUMTemperature 160°F [ 71°C]MED LOWTemperature 140°F [60°C]LOWTemperature 120°F [49°C]To use a Time Dry or Custom Cycle

Pagina 56 - TMB1666N_SVG

Make-Up Air...33Venting...

Pagina 57 - Control Instructions

S Models TMB1345R_SVG H Models TMB1346R_SVG Figure 34U Models TMB1371R_SVG Y Models TMB2370N_SVGSTARTSTOPBACK Figure 35C, D, and I Models TMB1375R_SVG

Pagina 58 - Operating Instructions

1. Press the or keypad to change cycles. The center high-lighted position is the selected cycle.To customize a cycle, refer to the Programming Ma

Pagina 59 - REVERSING

WARNINGTo prevent the risk of fire, remove laundry imme-diately in case of power failure.W779 Diagnostic Microprocessor ControlGeneral OperationThe Di

Pagina 60

Description of the OPL Control PanelTMB1956N_SVG68782134510111291. START. Starts or resumes the current program or cycle.2. STOP. Temporarily halt

Pagina 61

Function OPL Coin7 Safety Tumble (OPL) or CoinCount/Pay (Coin)ON OFF #1 #7 DIP SWITCHOFF ON SAFETY TUMBLEOFF OFF NO SAFETY TUM-BLEON ON COIN COUNTON O

Pagina 62

Fault Conditions2 Flashes Flame Without Call For Heat3 Flashes Ignition Lockout4 Flashes (70458701 only) Manual Reset ErrorSteady On Internal Control

Pagina 63

Troubleshooting GuideReset failure 1. Reset switch was pressed too long. Try to reset again.2. Reset switch is shorted. Replace switch. Proper Electro

Pagina 64

Lockout Mode. If no faults are detected, the Diagnostic LED willturn Green and the ignition control will enter Standby Mode.Standby ModeWhile in Stand

Pagina 65

LED ColorDescriptionRed Fault Indication CodeTable 11The Diagnostic LED will flash error codes one half second onand one half second off. Error codes

Pagina 66 - Models Through 3/10/13

Adjustments AdjustmentsWARNINGTo reduce the risk of electric shock, fire, explosion,serious injury or death:• Disconnect electric power to the tumble

Pagina 67

Diagnostic LED (DGN LED)/Error Codes...67Adjustments...

Pagina 68

T464I_SVG1424341. Proper Airflow2. Insufficient Airflow3. No Airflow4. Air Shutter Adjusting ScrewFigure 43 Airflow SwitchThe airflow switch i

Pagina 69 - Adjustments

Loading Door Strike (200 Series Mod-els)The loading door strike must be adjusted to have sufficient ten-sion to hold loading door closed against forc

Pagina 70 - Loading Door Switch

Maintenance Daily1. Inspect the area surrounding tumble dryers, remove all com-bustible materials, including lint, before operating the ma-chines.2.

Pagina 71 - Belt Drive

8. Inspect cabinet and inner panels for any damage, replace orrepair as needed.9. Clean burner tubes and orifice area of any lint buildup.10. Mac

Pagina 72 - Maintenance

DryWeightWetWeightMini-mumWeightlbs.[kg]lbs.[kg]lbs.[kg]120 60 [27] 75-79[34-36]70 [32]170 80 [36] 95-99[43-45]90 [41]200 100 [45] 115-119[52-54]110 [

Pagina 73 - Equipment) Maintenance Test

Before You Call for ServiceWon’t Start Won’t Heat Clothes Not Dry Possible Reason – Corrective Actions• Insert correct coin(s) or valid card if applic

Pagina 74

Removing Tumble Dryer from Service1. Turn off electrical supply external to machine.2. Turn off electrical disconnect on machine.3. Turn off gas

Pagina 75 - Before You Call for Service

Disposal of UnitThis appliance is marked according to the European directive2002/96/EC on Waste Electrical and Electronic Equipment(WEEE).This symbol

Pagina 76

Introduction Model IdentificationInformation in this manual is applicable to these models:Gas Steam/Thermal Oil Electric120 Series CA120LCA120NCK120NC

Pagina 77 - Disposal of Unit

Gas Steam/Thermal Oil Electric170 Series CA170LCA170NCK170NCT170LCT170NCU170LCU170NDR170G2-BA170LDR170G2-BA170NDR170G2-BK170NDR170G2-BT170LDR170G2-BT1