ALLIANCE AE7133 Manuale di Servizio Pagina 35

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 34
34 60549
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
To Test Sensor
(Gas Models)
1. Remove wires from sensor terminals. Refer to
Figure 18.
2. Set test meter to read OHMS and put meter
probes on sensor terminals. Meter should read
zero Ohms. If meter registers an Ohm reading
of any amount, replace sensor.
NOTE: Test procedure can be performed on
workbench if gas valve, igniter, burner tube and
burner housing have been removed from dryer.
Figure 18
D241S
HEAT
SHROUD
SCREW
BURNER
HOUSING
BURNER TUBE
SCREW
SENSOR
ATTACHING
SCREW
UNION
NUT
SENSOR
TAB
GAS
SHUT-OFF
VALVE
(Shown in the
off position)
IGNITER
DISCONNECT
BLOCK
GAS
VALVE
IGNITER
Vedere la pagina 34
1 2 ... 30 31 32 33 34 35 36 37 38 39 40 ... 124 125

Commenti su questo manuale

Nessun commento